SPX FLOW COPES-VULCAN

MNSD MULTIPLE NOZZLE SPRAY DESUPERHEATER

MNSD MULTIPLE NOZZLE SPRAY DESUPERHEATER

  • The Copes-Vulcan Multiple Nozzle Spray Desuperheater offers optimum performance and rangeability in a variable spray tube design. The MNSD fills the performance gap between the limited capability of a simple mechanical spray type desuperheater and the virtually unlimited capability of Copes-Vulcan’s Variable Orifice Desuperheater. The MNSD offers high temperature capabilities and up to Class V leakage rating.

  • ✔︎ Temperature control to within 15°F (8°C) of saturation with the ability to hold set point within a tolerance of 10 °F (6°C)

    ✔︎ Standard maximum available Cv of 10.5 (Kv of 8.9)

    ✔︎ Water flow turndown of 150:1 or higher

    ✔︎ User friendly design - nozzles and trim assembly can be removed without disconnecting the actuator

    ✔︎ No need for separate cooling water control valve

    ✔︎ Designed for applications with temperatures up to 1150°F (620 °C)

    ✔︎ Available in standard classes 600, 900,1500 and 2500 per ANSI B16.5

    ✔︎ Cooling water inlet pressures up to 3500 psig (24 MPag)(higher pressures on application)

    ✔︎ FCI 70-2/ANSI Class IV or Class V shutoff capability

    ✔︎ Suitable for vertical or horizontal installation

    ✔︎ Standard ANSI connections are 3" (80mm) raised face flange (steam) and 1.5" (40mm) raised face flange (water)

    ✔︎ Designed to resist thermal fatigue